ControlByWeb manufactures IP based monitoring and control devices that provide various inputs and outputs such as relays, digital inputs, analog inputs, 1-wire bus for monitoring of temperature & humidity, etc.  Chowmain has integrated the X-310, X-320 and X-322 ControlByWeb devices into Control4 to expose their IO's for various integration requirements.

X-310 Features

  • 4 x relay outputs
  • 4 x sensor inputs
    • NOTE – Control4 polls the sensors. As such it may take upto 5 seconds for the input to respond. Do not use the inputs if timing is crucial.
  • Exposes values to variables for programming
    • Last Poll Time
    • Serial Number
    • Onboard Timestamp
    • Internal Temperature
    • Memory Power Up Flag
    • Device Power Up Flag
    • Power Loss Counter
    • Input 1 State
    • Input 2 State
    • Input 3 State
    • Input 4 State
    • Relay 1 State
    • Relay 2 State
    • Relay 3 State
    • Relay 4 State
    • High Time 1
    • High Time 2
    • Raw Count 1
    • Raw Count 2
    • Voltage Input
    • Voltage Input Alarm
    • Units
    • Sensor 1 Temp
    • Sensor 2 Temp
    • Sensor 3 Temp
    • Sensor 4 Temp
    • Sensor 1 Alarm
    • Sensor 2 Alarm
    • Sensor 3 Alarm
    • Sensor 4 Alarm
    • Count 1
    • Count 2
    • Extra Variable 0
    • Extra Variable 1
    • Extra Variable 2
    • Extra Variable 3
  • Programming Actions
    • Ability to clear memory flag
    • Ability to clear device flag
    • Ability to clear power loss counter

X-320 Features

  • 2 x Configurable GPIOs
    • Can be configured in either inputs or outputs
  • Exposes values to variables for programming
    • Last Poll Time
    • Serial Number
    • Onboard Timestamp
    • Internal Temperature
    • Internal Voltage
    • Memory Power Up Flag
    • Device Power Up Flag
    • Power Loss Counter
    • IO1 State
    • IO2 State
    • IO1 Direction
    • IO2 Direction
    • High Time 1
    • High Time 2
    • Raw Count 1
    • Raw Count 2
    • Rate 1
    • Rate 2
    • Raw Frequency
    • Frequency
    • Frequency Alarm
    • Analog 1 State
    • Analog 2 State
    • Analog 3 State
    • Analog 4 State
    • Analog 1 Alarm
    • Analog 2 Alarm
    • Analog 3 Alarm
    • Analog 4 Alarm
    • Units
    • Sensor 1 Temp
    • Sensor 2 Temp
    • Sensor 3 Temp
    • Sensor 4 Temp
    • Sensor 5 Temp
    • Sensor 6 Temp
    • Sensor 1 Alarm
    • Sensor 2 Alarm
    • Sensor 3 Alarm
    • Sensor 4 Alarm
    • Sensor 5 Alarm
    • Sensor 6 Alarm
    • Extra Variable 0
    • Extra Variable 1
    • Extra Variable 2
    • Extra Variable 3
  • Programming Actions
    • Ability to clear memory flag
    • Ability to clear device flag
    • Ability to clear power loss counter

X-332 Features

  • 16 x relay outputs
  • 16 x sensor inputs (digital inputs) (NOTE – Control4 polls the sensors.  As such it may take upto 5 seconds for the input to respond.  Do not use the inputs if timing is crucial.)
  • 4 x analog inputs (as variables)
  • 4 x tempeature sensors

Exposes values to variables for programming

  • Last Poll Time
  • Serial Number
  • Onboard Timestamp
  • Internal Temperature
  • Memory Power Up Flag
  • Device Power Up Flag
  • Power Loss Counter
  • Analog 1 State
  • Analog 2 State
  • Analog 3 State
  • Analog 4 State
  • Analog 1 Alarm
  • Analog 2 Alarm
  • Analog 3 Alarm
  • Analog 4 Alarm
  • Input 1 State
  • Input 2 State
  • Input 3 State
  • Input 4 State
  • Input 5 State
  • Input 6 State
  • Input 7 State
  • Input 8 State
  • Input 9 State
  • Input 10 State
  • Input 11 State
  • Input 12 State
  • Input 13 State
  • Input 14 State
  • Input 15 State
  • Input 16 State
  • Relay 1 State
  • Relay 2 State
  • Relay 3 State
  • Relay 4 State
  • Relay 5 State
  • Relay 6 State
  • Relay 7 State
  • Relay 8 State
  • Relay 9 State
  • Relay 10 State
  • Relay 11 State
  • Relay 12 State
  • Relay 13 State
  • Relay 14 State
  • Relay 15 State
  • Relay 16 State
  • High Time 1
  • High Time 2
  • Raw Count 1
  • Raw Count 2
  • Units
  • Sensor 1 Temp
  • Sensor 2 Temp
  • Sensor 3 Temp
  • Sensor 4 Temp
  • Sensor 1 Alarm
  • Sensor 2 Alarm
  • Sensor 3 Alarm
  • Sensor 4 Alarm
  • Count 1
  • Count 2
  • Extra Variable 1
  • Extra Variable 2
  • Extra Variable 3
  • Extra Variable 4
  • Extra Variable 5
  • Programming Actions
    • Ability to clear memory flag
    • Ability to clear device flag
    • Ability to clear power loss counter

FAQ

What can i use this for?

These products are good for adding additional contacts, relays, temperature sensors and other analog sensors that are not native to Control4.

Why do you only support OS 2.6 and above?
OS 2.6 offers a superior security encryption algorithm and a new and improved driver format. We have decided to only utilise this new format to ensure that the integrity of this driver is not compromised and that we can provide the best dealer/user experience available.

What models will this work for?

We have currently integrated the X-310, X-320 and X-332 models.  We are looking at integrating other models.  Please speak to us if you are interested in helping us test other models.

Do you offer showroom discounts?
We offer dealers a free showroom licence for demonstration and educational purposes.  See link below for T&C's and signup procedure.

Chowmain Dealer Showroom FAQ

I want to try this driver out before buying it?
All Chowmain drivers for Control4 come with a 7 day trial.  Just add the driverCentral licencing driver and this driver and you're good to go.  No registration required.

Version #20170710 - 10-JUL-2017

  • Migrated to driverCentral.

Version #20160815 - 15-AUG-2016

  • Added support for the X-332

Version #20160405 - 05-JUL-2016

  • Initial Release